How Does My Pool Timer Work? | eHow After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? Voltage is 243, frequency is 60hz. Could I send you a picture of my setup? the problem lies, where the power dies as they say. There is power; gears are moving. The problem was the connections I made inside my main electrical panel, I used romex wire nuts to attach the solid core #10 wire that I used to hook up the timer to the existing stranded #10 wire and it didnt make the connection so to speak. Or there could be a bad relay in the control panel, if you have ice cube style relays. How about the GFCI outlet TEST button, is it tripped? My timer clock does not run and the manual on off switch does not turn off the pump motor. Thank you. For example, sometimes you can see a burnt wire or sometimes it may be as simple as the circuit breaker has been tripped. So out comes the soldering gun and the shrink wraps and that did the trick. 975 Telegraph Rd #103, Santa Paula, CA 93060 | MLS# V1-15365 | Redfin Only perform this step if you are qualified. Thank you for choosing Intermatic! "@type": "BlogPosting",
Hi Tanya, yes that sounds like it might be wired incorrectly, check the wiring diagram on the label, or if missing, you can find them online for your timer model. Hi David, I suppose that you could wire the T101 from the outlet, but Im not sure if that is in accordance with code. For some reason, whenever my timer hits the time its supposed to kick the pump on, it gets stuck at that time and the pump wont come on. If the motor gears are not turning, check the wire tightness (Breaker off first), and depress the tab at top to inspect the rear of the mechanism, to see if anything looks funny back there. So just turn the adjustment hold down screw on the timer pin counter clockwise about a full turn and then you will be able to slide the on or off pin to the right time on the timer wheel. Grab your torch and shine it in the holes. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and . Intermatic timer won't turn on/off pump. | Trouble Free Pool After this has been removed, you can turn the breaker back on and measure for the voltage on the timer input. Pool Pump Timer Not Working - Pool Research "publisher": {
The problem lies, where the power dies, as they say, Thanks for the response. That way I could schedule the pump once again. Black goes to _1 Look for any disconnected or damaged wires leading to the motor on the rear of the clock. Jun 3, 2013, 10:07 AM You will have ON trippers and OFF trippers, You can place an ON at Noon, and OFF at 1:00 for 1 hours operation, If you manually turned it back on at 3:00, it would stay on until the next OFF tripper (1:00). The timer motor cover (the oval silver box with the printing) can be pried off with a sharp screwdriver. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Hi, Required fields are marked *. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Professional plumber and home repairs expert, How To Remove Broken Hayward Super Pump Drain Plugs. It only takes a small amount of dirt to foul up gears so look carefully. They are: Heres how to troubleshoot a mechanical pool timer step-by-step: It goes without saying that you should be qualified if you intend on working with live power. If it doesnt, there could be an issue with the clock face or gears. The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. The other gears move very slowly, and appear to not move at all, except for one I believe? 2. Look to see if the clock is set to the correct time. I replaced the fuse(BUSS 300v GLR 3) as well. After securing the wire conduit (flexible or rigid) to the box, knock out with the proper 3/4 conduit connector. If its loose, grab a screwdriver and tighten it up. Do you have an answer to why my pump wont turn off or on? Reasons Why Pool Timers Stop Working 1. Sometimes those are looped back to the control box. It may or may not reduce the noise level however. },
Replace a new T104. I have a intermatic T101 and the clock doesnt move I replaced the old one due to burned out motor . Is it Necessary? Hi Carlos, is there a GFCI outlet in the circuit? Hi Tyler, maybe the dial is now pushed forward, far enough to where the trippers do not contact the switch? Simple Ways to Set a Pool Timer: 11 Steps (with Pictures) - wikiHow Recently i just notice my T104R timer a bit noisier than usual. Wont work manually or by timer function. Back when I was a young technician I was taught to always look for the easy things and use all my senses. "image": {
Other than a couple of weeks, we have spent fifteen years manually turning on our pump. The mechanism for the off tripper doesn't work at all when manually depressed. Should You Get a Pool Pump Timer? The Intermatic Model T104R Timer that turns on and off the motor on my pool recently, about two or three times week, trips my GFCI requiring me to reset it which has been increasing very hard to to reset. And when switched on, power to the load terminals? Perhaps bad wiring or a bad breaker is to blame. Hi Davy, Intermatic pool timers allow you to set specific run-times for your pool filter pump, booster pump, and waterfall pump, so they operate at the most convenient time, or during non-peak energy hours. I have an Intermatic t104. The screw in the center point timer occasionally comes loose due to vibrations from the pump and filter. Monday the clock face was free spinning, today when I got home it had broken and fallen off. However, since I did that the time clock stopped working I looked at the motor visual window and nothing is moving. You can manually engage it by turning it and then it will run and even SHUT OFF when its supposed to. Terminal A (farthest to the left side) is not connected to anything. Posted by 4 years ago. please help me. Partially loosen the screw that holds the "off" pin in place. },
I looked to see if the gears on the timer are running. Is the ON tripper all the way pushed onto the dial? If moving that is difficult, you could just avoid using the switch and turn the pump off with the timeclock instead, always keeping the switch on, and maybe taping the switch, to remind people not to use the switch. We cover T101, T103 and T104 models of mechanical pool timers. The BN-LINK compact outdoor mechanical pool pump timer is programmable in 15-minute intervals with 48 setting options in a 24 hours period. Why it always stop around 10pm by itself and not moving again? But if your circuit breaker is in the on position and your pool timer clock is not rotating and the timer is not working then you will need to call a licensed electrician to replace the timer. Just some ideas. Is power reaching the time clock? Hi Rhomell, are you sure you got the correct trippers? I not sure if this is the best timer to use. I need to replace a timer for my pool vacuum. The timer appears to be working fine (keeps time). If its not, then the timer will not turn on/off at the correct times. There should be an off pin and an on pin. Stupid third question, but does the ON tripper say ON? Timer must be reset for current time after power outage. I found a diagram showing neutral to A, line 1 to terminal 1 and line 2 to terminal 3. When you flip the switch does it separate and reconnect the tabs? },
Was a good island when all the day trippers left - Review of South Sea With the breakers turned off, remove the mechanism from the box. Hi, Davy, seeing lots of complaints here. If the motor or wires are faulty in your Intermatic time clock, its time to replace the mechanism. Any advice? Hello. You can have as many ON an OFF trippes as you want. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Sound right? Thanks. It could also be loose wires, either on the time clock terminal board, or on the timer motor. Resolved! Basically 12 real life hours equals about 14 on the timer. Watch these tips and tricks before replacing it. Hi Ryan, that sounds like a bad motor or a broken gear, you can replace just the motor, or the entire clock mechanism. Power surges could be to blame.